DEKON VRF UNITS

DEKON VRF air conditioner X series DC inverter Out door units modular type under T3 conditions

 

DEKON VRF air conditioner X series Full DC Inverter technology

DC inverter Hitachi compressor

Working temperature from -5 to 52 degrees, T3 conditions

2 pipe system now, and 3 pipes system coming soon.

Modular design, can be max 3 module connected together.

Single module: 8/10/12/14/16/20/22HP

Combination Module: 24HQ up to 66HP

 

 

 

China factory of VRF air conditioner|DC inverter Out door units modular type} 34HP 96KW under T3 conditions

China factory of VRF air conditioner|DC inverter Out door units modular type} 34HP 96KW under T3 conditions

China factory of VRF air conditioner|DC inverter Out door units modular type} 34HP 96KW under T3 conditions

 

 

Below is the introduction of Modular type Out door units:

 

Cooling capacity 96kw/34HP

Model No. DRV340AX = Combination of DRV140AX and DRV200AX

 

China factory of VRF air conditioner|DC inverter Out door units modular type} 34HP 96KW under T3 conditions

 

DEKON DRV X series specifications:

 

Dekon Model DRV080AX DRV100AX DRV120AX DRV140AX DRV160AX DRV180AX DRV200AX DRV220AX
Combination model
Capacity Capacity range HP 8 10 12 14 16 18 20 22
Cooling kW 25 28 33.5 40 45 50 56 61.5
Heating kW 27 31.5 37.5 45 50 56 63 69
Power supply V/N/Hz 380V/3N/50Hz/60Hz
EER kW/kW 4.08 3.95 3.88 3.75 3.56 3.53 3.6 3.68
COP kW/kW 4.45 4.49 4.36 4.25 3.99 3.96 4.06 4.14
Rated input Cooling kW 6.12 7.09 8.63 10.67 12.64 14.16 15.56 16.71
Heating kW 6.07 7.02 8.6 10.58 12.6 14.12 15.52 16.65
Rated Cooling A 12.5 13.4 16.4 19.6 24.1 30.5 35.2 40
current Heating A 13.6 13.9 16.7 20 24 30.1 34.9 35
Refrigerant Type R410A
Charge volume kg 8 10 12 16
Compressor Brand Hitachi
Type Scroll type
Quantity 1 1+1
Refrigerant oil L 0.5 1.1 0.5 0.5
charge volume
Fan Type Axial flow
Quantity 1 1+1
Fan motor Insulation class IP24
Drive Type DC
Airflow rate m3/h 12000 13980 18780 20820 22020
Connecting pipe Liquid pipe mm φ12.7 φ12.7 φ12.7 φ15.88
Gas pipe mm φ22.23 φ25.4 φ28.58 φ28.58
Connection method Welding
ESP Pa 0-80
Sound pressure level dB(A) 45-57 45-59 45-62 45-63
Outline dimension mm 930*860*1710 1240*860*1710 1500*860*1710 1500*860*1710
Package dimension mm 930*860*2000 1240*860*2000 1500*860*2000 1500*860*2000
Net weight kg 225 225 225 290 290 430 430 430
Gross weight kg 245 245 245 310 310 450 450 450
Maximum drive IDU NO. unit 14 16 19 22 23 31 33 34
Max. equivalent connection m 240 240 240 240 240 240 240 240
pipe length
Working temp. Cooling °C -5-52°C
Heating °C -20-24°C

 

DEKON VRF air conditioner-China Professional VRF supplier/factory for many years.

We have exported DEKON DRV Air conditioner to more than 20 different countries.

If need selection or designing for your project, pls contact us directly by mail.

Or scan below code on the picture shown.

China factory of VRF air conditioner|DC inverter Out door units modular type} 34HP 96KW under T3 conditions

 

China factory of VRF air conditioner|DC inverter Out door units modular type} 34HP 96KW under T3 conditions

 

Our designed project for Bolivia project.

 

China factory of VRF air conditioner|DC inverter Out door units modular type} 34HP 96KW under T3 conditions

 

Below is the detailed introduction for DEKON VRF System control ways:

 

China factory of VRF air conditioner|DC inverter Out door units modular type} 34HP 96KW under T3 conditionsChina factory of VRF air conditioner|DC inverter Out door units modular type} 34HP 96KW under T3 conditions

China factory of VRF air conditioner|DC inverter Out door units modular type} 34HP 96KW under T3 conditions

China factory of VRF air conditioner|DC inverter Out door units modular type} 34HP 96KW under T3 conditionsChina factory of VRF air conditioner|DC inverter Out door units modular type} 34HP 96KW under T3 conditions

China factory of VRF air conditioner|DC inverter Out door units modular type} 34HP 96KW under T3 conditions

China factory of VRF air conditioner|DC inverter Out door units modular type} 34HP 96KW under T3 conditions

China factory of VRF air conditioner|DC inverter Out door units modular type} 34HP 96KW under T3 conditions

 

 

Brief introduction about DEKON VRF System.

 

1. Environmental and healthy
A. DC inverter module uses of R410A refrigerant, non destruction to the ozone layer, energy saving, environmental protection and pollution-free;
B. All materials of DC inverter module comply with RoHS environmental directive.
2. Reliable and durable
Adopted Hitachi compressors, efficient, reliable, frequency and fully verified.
3. High efficiency and energy saving
A. DC inverter module uses Hitachi compressor high-performance high efficiency ;
B. DC inverter module uses advanced output capacity control technology, according to the indoor, outdoor temperature and load of indoor unit, automaticallyadjust system output capacity, so that indoor can remain in a stable and comfortable temperature, reaching high efficiency and energy saving effect;
C. In cooling mode, EER can achieve up to 4.18, with average EER 3.55;
D. In heating mode, COP can achieve up to 4.37, with average COP 3.96;
4. Long piping design
Maximum length of pipeline up to 150 meters, the max.
Height difference between indoor and outdoor unit up to 50 meters, widely use;
5. Wide operation temperatureCooling operation temperature: -5 ~ 50 degrees
Heating operation temperature: -15 ~ 28 degrees
6. Intelligent control
Our VRF unit only uses one set of control software can manage up to 4096 sets indoor units, canculating each indoor unit as 5HP, total management over 20, 000HP.

 

If you have other request you can also view:

 

 

China good factory for Air Handling Units with ABB motor Yilida fan double layer panel EC motor is optional China good factory for Air Handling Units with ABB motor Yilida fan double layer panel EC motor is optional
Air handling unit Air cooled screw chiller
China good factory for Air Handling Units with ABB motor Yilida fan double layer panel EC motor is optional China good factory for Air Handling Units with ABB motor Yilida fan double layer panel EC motor is optional
Water cooeld screw chiller Packaged rooftop units
China good factory for Air Handling Units with ABB motor Yilida fan double layer panel EC motor is optional China good factory for Air Handling Units with ABB motor Yilida fan double layer panel EC motor is optional
High ESP FCU Four way cassette FCU
China good factory for Air Handling Units with ABB motor Yilida fan double layer panel EC motor is optional China good factory for Air Handling Units with ABB motor Yilida fan double layer panel EC motor is optional
Modular scroll chiller Mini Chiller
China good factory for Air Handling Units with ABB motor Yilida fan double layer panel EC motor is optional China good factory for Air Handling Units with ABB motor Yilida fan double layer panel EC motor is optional
Light commercial AC Centrifugal chiller

 

Catalog for VRF-Rooftop-Light commercial air conditioner

Catalog for Chiller, AHU, FCU

For more info, please mail us directly to info@dekon-china.com.

Or add whatsapp 0086-15356475680/Simon